Practice Set: Redox, Electrochemistry and Solubility

Eight practice problems on oxidation numbers, cell potentials, Nernst, electrolysis, Ksp and precipitation, with worked checks you can run.

This second practice set covers redox, electrochemistry and solubility. As before, try each problem yourself, then run the checking programs. Use the standard potentials from the galvanic cells lesson: Ag⁺/Ag = +0.80 V, Zn²⁺/Zn = −0.76 V. Constants: F = 96485 C/mol, R = 8.314 J mol⁻¹ K⁻¹, T = 298.15 K.

The problems

1. Oxidation numbers. Find the oxidation number of (a) Cl in HClO4, (b) Mn in MnO2, (c) S in S2O3²⁻.

2. Cell potential. A cell uses a silver electrode (Ag⁺/Ag) and a zinc electrode (Zn²⁺/Zn). Identify cathode and anode, write the overall equation and find E°cell.

3. Free energy. For the cell in problem 2, calculate ΔG° in kJ/mol of reaction (n = 2).

4. Nernst. The same cell has [Zn²⁺] = 0.10 M and [Ag⁺] = 0.010 M. Find E.

5. Electrolysis. How much nickel (Ni²⁺ + 2 e⁻ → Ni, M = 58.69 g/mol) is deposited by 0.500 A in 2.00 hours?

6. Ksp. Find the molar solubility of Ag2CrO4, Ksp = 1.1 × 10⁻¹².

7. Precipitation. 100.0 mL of 2.0 × 10⁻⁴ M Ca²⁺ is mixed with 100.0 mL of 4.0 × 10⁻⁴ M F⁻. Does CaF2 (Ksp = 3.9 × 10⁻¹¹) precipitate?

8. Common ion. What is the solubility of CaF₂ in 0.010 M NaF?

Hints

  • Problem 1(c): the thiosulfate ion has two S atoms, and the average oxidation number is what the rule gives.
  • Problem 2: the more positive E° is reduced.
  • Problem 4: Q = [Zn²⁺] / [Ag⁺]² for Zn + 2 Ag⁺ → Zn²⁺ + 2 Ag.
  • Problem 5: Q = It, then n(e⁻) = Q/F, divide by 2.
  • Problem 7: halve each concentration, then use Q = [Ca²⁺][F⁻]².
  • Problem 8: s (0.010 + 2s)² = Ksp, and 2s is negligible.

Check your answers

Python Answer checker for problems 1 to 5

Press Run (or Ctrl + Enter) to see the result here.

Program input · what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

For problem 1(c), the average oxidation number of sulfur in thiosulfate is +2, even though the two sulfur atoms really differ (one is like sulfate's sulfur, one like a sulfide). Oxidation numbers are an accounting tool.

Python Answer checker for problems 6 to 8

Press Run (or Ctrl + Enter) to see the result here.

Program input · what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

Problem 7's mixture is below Ksp (about 4 × 10⁻¹² against 3.9 × 10⁻¹¹), so there is no precipitate. For problem 8, compare with the solubility of CaF₂ in pure water, which is roughly (3.9×10⁻¹¹/4)^(1/3) = 2.1×10⁻⁴ M: the common ion lowers it by about a factor of 500.

Extra challenges

  • Write the balanced half-reactions for the cell in problem 2 and check them with the atom and charge checker from the balancing lesson.
  • At what ratio [Zn²⁺]/[Ag⁺]² does the cell reach E = 0? (Set Q = K; K for this cell is enormous.)
  • How long would problem 5 take to deposit 10.0 g of nickel at the same current?

Check your understanding

Quick check · 4 questions

of 4 answered You scored / 4 · perfect!

  1. 1. In a cell with Ag+/Ag (+0.80 V) and Zn2+/Zn (-0.76 V), which metal is the anode?

    The species with the lower E° is oxidized. Zinc has the more negative potential, so it is the anode.
  2. 2. In Nernst-equation problems, what does a larger Q do to E?

    E = E° - (RT/nF) ln Q, so a larger Q lowers E.
  3. 3. Q for a precipitation check is computed from...

    Mixing dilutes each ion, so the ion product must use the final concentrations.
  4. 4. What is the effect of 0.010 M NaF on the solubility of CaF2?

    Fluoride is a common ion, so the dissolution equilibrium shifts toward the solid.

Summary

  • Oxidation numbers follow from the sum rule.
  • E°cell = E°cathode − E°anode; ΔG° = −nFE°; Nernst corrects for concentrations.
  • Faraday's laws connect current, time and mass.
  • Ksp gives solubility with the right ion ratio; Q versus Ksp predicts precipitation with diluted concentrations.
  • A common ion cuts solubility sharply.