Skip to content
Tutorials Center
My learning

Topics

Lesson 3 of 39 ยท Getting Started

Lab Equipment and Measuring Tools

Meet the glassware, balances and heating tools of a chemistry lab, learn which are precise, and see how to read a scale and estimate uncertainty.

A chemist's results are only as good as the tools used to get them. Some glassware is made for holding liquids, and some is made for measuring them. Mixing these up is one of the most common beginner mistakes. In this lesson you will meet the main tools and learn how to choose and read them.

Containers and heating

These are for holding, mixing and heating, not for exact measuring.

  • Beaker: a wide cup with a spout. Its volume marks are only rough guides, often within 5 to 10 percent.
  • Erlenmeyer flask (conical flask): a cone with a narrow neck. Swirling mixes the contents without spilling.
  • Test tube: a small glass tube for small reactions; hold it with a holder when heating.
  • Evaporating dish: a shallow dish for boiling a liquid away to leave a solid.
  • Bunsen burner or hot plate: the heat source. Never leave one unattended.
  • Tongs, clamps and stands: for holding hot or awkward items.

Tools for measuring

Tool Measures Typical use
Electronic balance Mass Weighing solids to 0.01 g or 0.001 g
Graduated cylinder Volume Measuring liquids to moderate precision
Pipette (volumetric) One fixed volume Delivering exactly, for example, 25.00 mL
Burette Volume dispensed Adding liquid slowly, drop by drop, in titrations
Thermometer Temperature Measuring in degrees Celsius
Volumetric flask One fixed volume Making solutions of exact volume

The more digits a tool lets you read, the more precise it is. A beaker marked 100 mL is poor for measuring. A 100 mL graduated cylinder is better, and a 25 mL volumetric pipette is best for delivering 25 mL.

Hold, mix, measure

Beaker Holds and mixes. Rough volume only.
Graduated cylinder Measures liquid volume.
Balance Measures mass.
Pipette or burette Exact volumes.
1 / 2

Reading a scale correctly

When you read a graduated cylinder, the water surface curves. This curve is called the meniscus. For water and most solutions you read the bottom of the meniscus with your eye level to the liquid, to avoid parallax error. Mercury is an exception, because it curves the other way.

The rule for reading any scale:

  1. Find the smallest marked division.
  2. Read to that mark.
  3. Estimate one more digit between the marks.

If a cylinder is marked every 1 mL, you read to the nearest 0.1 mL, for instance 37.4 mL. The last digit is an estimate, and it is still meaningful. This idea reappears in Significant Figures.

Python Reading a burette

Press Run (or Ctrl + Enter) to see the result here.

Program input ยท what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

Uncertainty and percent error

Every tool has an uncertainty. A reading of 25.0 ยฑ 0.5 mL means the true volume is probably between 24.5 and 25.5 mL. A tool with a smaller uncertainty relative to the amount measured is more useful. That relative size is the percent uncertainty:

percent uncertainty = (uncertainty / measured value) ร— 100

You can also compare a result with an accepted value:

percent error = |experimental - accepted| / accepted ร— 100

The uncertainties below are illustrative round numbers chosen for teaching. Real tools list their tolerances on the glass or in the manual.

Python Which tool gives the smallest relative uncertainty?

Press Run (or Ctrl + Enter) to see the result here.

Program input ยท what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

Zero a balance with the empty container on it (this is called taring), and read it with the doors closed, because air currents change the reading.

Quick check ยท 4 questions

of 4 answered You scored / 4 ยท perfect!

  1. 1. Which tool should you choose to deliver exactly 25.00 mL?

    A volumetric pipette is built to deliver one precise volume. Beakers and flasks only give rough volumes.
  2. 2. A graduated cylinder is marked every 1 mL. To what precision should you read it?

    Read to the smallest mark and estimate one more digit, which gives 0.1 mL here.
  3. 3. Where do you read a water meniscus?

    For water the curve dips downward, so you read the lowest point, with your eye level to it.
  4. 4. A burette reads 4.10 mL at the start and 19.60 mL at the end. How much was dispensed?

    19.60 - 4.10 = 15.50 mL.

Summary

  • Beakers and flasks hold liquids; cylinders, pipettes and burettes measure them.
  • Choose the tool with the smallest uncertainty for the job.
  • Read a scale to its smallest division and estimate one more digit; read water at the bottom of the meniscus.
  • Percent uncertainty and percent error tell you how good a measurement is.
  • Tare a balance and keep its doors closed while weighing.

Next: How to Study Chemistry