Project: A Weather Station with Logging and Averages

Build a Raspberry Pi weather station: read a BME280 over I2C, calibrate and smooth values, store readings in SQLite, and compute hourly averages and min/max.

A weather station is the classic first Pi project because it touches every skill at once: reading a sensor, timing a loop, storing data, and turning raw numbers into something useful. Our design is small enough to finish in an evening and solid enough to run for months: one sensor, one Python program, one SQLite database, one systemd service.

The BME280 sensor cannot be attached to this website, so hardware code is read-only. Everything else (the data model, the averaging, the database queries, the outlier filter) is written in Python you can run here with a simulated sensor. Replace the simulator with the real read function and the rest works unchanged.

What you need

  • Any Raspberry Pi with Raspberry Pi OS and I2C enabled (sudo raspi-config, Interface Options).
  • A BME280 breakout (temperature, humidity, pressure). Wire 3.3 V to VIN, GND to GND, SDA to GPIO 2 (pin 3), SCL to GPIO 3 (pin 5).
  • Optional: a case that keeps the sensor away from the Pi's own heat, since a CPU warms the air next to it.

Check the sensor is visible on the bus:

Terminal
sudo apt install i2c-tools python3-smbus
i2cdetect -y 1        # expect 76 or 77 in the grid

The reading code

With the Adafruit library (pip install into a virtual environment, as described in the earlier chapters) a reading is three lines:

Python
import board, adafruit_bme280.basic as bme280

i2c = board.I2C()
sensor = bme280.Adafruit_BME280_I2C(i2c, address=0x76)
print(sensor.temperature, sensor.relative_humidity, sensor.pressure)

Wrap it in a function that returns a dictionary, so the rest of the program never cares where the numbers come from. For this lesson we use a simulated source with the same shape:

Python A simulated sensor with the same interface

Press Run (or Ctrl + Enter) to see the result here.

Program input ยท what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

Storing readings in SQLite

SQLite is a database in a single file, with Python support built in. It beats a CSV when you want queries ("average per hour"), survives crashes without a half-written line, and lets two programs read while one writes. This block builds the table and inserts a day of simulated readings, one every 10 minutes, in an in-memory database (use a path like /home/ana/weather/weather.db on the Pi).

Python Create the table and insert a day of data

Press Run (or Ctrl + Enter) to see the result here.

Program input ยท what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

Always use ? placeholders instead of formatting values into the SQL string. It prevents injection and handles quoting for you.

Filtering bad readings

Real sensors occasionally return a wild value (an I2C glitch, a cable wiggle). Before storing, reject numbers outside physical limits and smooth with a median of the last few samples, which ignores single spikes better than an average.

Python Reject glitches and smooth with a median

Press Run (or Ctrl + Enter) to see the result here.

Program input ยท what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

The 85.9 passes the range test but the median keeps the line smooth; it would still be recorded raw in the database, so the better design stores both raw and smoothed values when debugging a sensor.

The main loop

Put it all together. Sleep for a fixed interval, handle errors without exiting, and log what happens:

Python
import sqlite3, time, traceback

DB = "/home/ana/weather/weather.db"
INTERVAL = 600   # seconds

def main():
    db = sqlite3.connect(DB)
    db.execute("CREATE TABLE IF NOT EXISTS readings (ts TEXT, temp_c REAL, humidity REAL, pressure_hpa REAL)")
    while True:
        try:
            r = read_real_sensor()
            if valid(r):
                db.execute("INSERT INTO readings VALUES (datetime('now'),?,?,?)",
                           (r["temp_c"], r["humidity"], r["pressure_hpa"]))
                db.commit()
        except OSError:
            traceback.print_exc()       # goes to the journal
        time.sleep(INTERVAL)

main()

Store timestamps in UTC (datetime('now') is UTC) and convert for display. Run this as a systemd service so it starts at boot and restarts after an I2C error. Check it with sqlite3 weather.db "SELECT * FROM readings ORDER BY ts DESC LIMIT 5;".

flowchart LR
    A["BME280"] -->|"I2C"| B["read_sensor()"]
    B --> C["validate and smooth"]
    C --> D["SQLite file"]
    D --> E["Web page or chart"]

From sensor to storage: each step has one job.

Making it useful

  • Calibration: compare against a trusted thermometer for a day. If yours reads 1.2 degrees warm, subtract an offset in one constant.
  • Placement: shade and ventilation matter more than the sensor. Mount it outdoors in a radiation shield, away from walls.
  • Dashboard: expose /api/latest and /api/hourly with the web server lesson, or publish values over MQTT.
  • Retention: at one reading per 10 minutes you add about 52,000 rows a year, which is tiny. Even so, plan to delete or aggregate old rows if you sample faster.

Check your understanding

Quick check ยท 4 questions

of 4 answered You scored / 4 ยท perfect!

  1. 1. Why use ? placeholders in SQLite statements?

    The driver passes values separately from the SQL text, so they cannot change the query.
  2. 2. Which smoothing method best ignores one-off spikes?

    A median is not pulled by a single extreme value.
  3. 3. On which pins does I2C live on a Pi (BCM numbering)?

    Bus 1 uses GPIO 2 for SDA and GPIO 3 for SCL (physical pins 3 and 5).
  4. 4. Why store timestamps in UTC?

    UTC has no clock changes; convert to local time only when showing data.

Summary

  • Isolate the sensor behind one function that returns a dictionary.
  • Validate against physical limits and smooth with a median.
  • Store readings in SQLite with UTC timestamps and parameterized inserts.
  • Run the loop as a service that survives errors and reboots.
  • Calibrate and place the sensor carefully; it matters more than code.