Skip to content
Tutorials Center
My learning

Topics

Lesson 2 of 36 ยท Getting Started

Installing LabVIEW and First Launch

Understand LabVIEW editions, NI Package Manager, drivers and modules, then tour the Getting Started window and create your first blank VI.

Before you can draw a VI you need the development environment, and usually some hardware drivers. LabVIEW is a desktop product, so this lesson describes the real installation workflow in words. Nothing here can run on this site; the stand-ins at the end are JavaScript helpers that model version and compatibility checks. Menu names can shift slightly between releases, so treat the steps as a guide and trust your own installer.

Editions and licensing

NI sells LabVIEW in tiers. Names and prices change over time, so check NI's website, but the pattern has been stable:

  • A base edition with the core language, front panel controls and basic analysis.
  • A full edition that adds more analysis, signal processing and tools.
  • A professional edition with application builder tools, unit-testing support and source-code control integration.
  • Add-on modules for specific jobs: Real-Time, FPGA, Control Design and Simulation, Vision, Database Connectivity, and others.

Students and teachers often use an academic license, and NI has at times offered a free non-commercial edition. If you are not sure which you need, start with a trial.

Bitness and versions

LabVIEW has been released in 32-bit and 64-bit builds. Modern releases use a year-based version name (for example a "2025 Q3" style release). A few rules help avoid pain:

  1. A VI saved in a newer version will not open in an older one unless you use Save for Previous Version.
  2. Drivers and toolkits must match the bitness of the LabVIEW you installed. A 64-bit LabVIEW needs 64-bit drivers.
  3. Keep project teams on one version.

The installation flow

  1. Create or sign in to an NI account.
  2. Download and run NI Package Manager. This is the tool that installs, updates and removes NI software.
  3. In Package Manager, search for LabVIEW, choose the version, and add it to the list. Package Manager resolves dependencies for you.
  4. Add the drivers you need. The most important ones:
    • NI-DAQmx for data-acquisition hardware.
    • NI-VISA for talking to instruments over GPIB, USB, serial and Ethernet.
  5. Install, then reboot if asked.
  6. Activate the license: Help > Activate inside LabVIEW, or through NI License Manager.

Install order

NI account
Package Manager
LabVIEW
Drivers

Drivers last, once LabVIEW is in place.

1 / 2

Measurement & Automation Explorer

Alongside LabVIEW you get NI MAX (Measurement & Automation Explorer). It lists the hardware the computer can see and lets you test it without writing any code. You can do a self-test of a DAQ device, open a test panel to read a channel, or create simulated devices. A simulated device is very useful when you have no hardware: your VI can run against it and behave like it is talking to the real thing.

First launch: the Getting Started window

When LabVIEW starts you see the Getting Started window. It is a small hub, not an editor. Typical items:

  • Create Project and Open Existing buttons.
  • A list of recent projects and files.
  • Links to examples and online resources.
  • The Find Examples entry, which opens the example finder.

Choose File > New VI. LabVIEW opens two windows: an empty front panel with a grey or white background, and an empty block diagram. Press Ctrl+E to flip between them, and Ctrl+H to show or hide the Context Help window, which documents any object you hover over. Context Help will become a constant companion.

The example finder

LabVIEW ships with hundreds of working examples. Open Help > Find Examples, search for a word like "acquire" or "string", and open one. Reading examples is one of the quickest ways to learn which function to use. When you find a useful pattern, copy the piece you need into your own VI instead of editing the example in place.

Environment options

Under Tools > Options you can set habits that matter:

  • Environment: autosave, colour of the grid, and whether new VIs open on the block diagram.
  • Block Diagram: enable Auto wire routing, and show tip strips.
  • Front Panel: control sizes.
  • Paths: where LabVIEW looks for VIs and where it saves.

Turn on autosave early. Crashes are rare but unsaved work is painful.

Troubleshooting checklist

  • Driver not found in LabVIEW palette: the driver bitness probably does not match.
  • Device missing in NI MAX: check cables and power; refresh the list; try a simulated device first.
  • Cannot open a VI: it was saved in a newer version, or it needs a toolkit you lack.
  • Missing VIs on load: LabVIEW shows a Find dialog; point it at the folder with the dependency.

A small stand-in: version compatibility

This JavaScript stand-in encodes the rule that a VI opens only in the same or a newer LabVIEW version. It is not NI code; it is a model of the rule so you can test examples.

JS Stand-in: can this VI open?

Press Run (or Ctrl + Enter) to see the console output here.

No output.

And one more stand-in for planning: a driver checklist that reports what is still missing for a task.

JS Stand-in: driver checklist

Press Run (or Ctrl + Enter) to see the console output here.

No output.

Check your understanding

Quick check ยท 4 questions

of 4 answered You scored / 4 ยท perfect!

  1. 1. Which tool installs and updates NI software?

    NI Package Manager resolves dependencies and installs LabVIEW, drivers and modules.
  2. 2. Which driver package is used for data-acquisition hardware?

    NI-DAQmx handles DAQ devices; NI-VISA handles instruments.
  3. 3. A VI saved in a newer LabVIEW version can be opened in an older one without any action.

    Newer VIs do not open in older versions unless saved for a previous version.
  4. 4. What is a simulated device in NI MAX useful for?

    Simulated devices behave like real hardware so you can develop without it.

Summary

  • Install LabVIEW with NI Package Manager, then add drivers such as NI-DAQmx and NI-VISA.
  • Match driver bitness to the LabVIEW bitness and keep a team on one version.
  • NI MAX shows hardware, tests it, and can create simulated devices.
  • The Getting Started window is a hub; File > New VI opens a front panel and block diagram.
  • Context Help (Ctrl+H) and Find Examples are the fastest learning aids.

Next: Front Panel and Block Diagram