Dominant Poles and the Effect of Added Poles and Zeros

Learn when a high-order system acts like a second-order one, how an extra pole slows a response, how a zero adds overshoot, with simulations in Python.

Real systems are rarely second order. A motor has electrical dynamics, a sensor has a lag, a filter adds a pole. Yet the second-order formulas still guide design, because often one pair of poles dominates. This lesson explains when that approximation holds, and what happens to the step response when you add a pole or a zero.

Dominant poles

Each pole contributes a mode e^(p t) to the response. A pole far to the left decays much faster than one near the imaginary axis, so after a short time only the slow modes remain. The poles closest to the imaginary axis are the dominant poles.

A common rule of thumb: if the other poles have real parts at least 5 to 10 times farther left than the dominant pair, the system behaves almost like a second-order system with just the dominant poles (and a matched DC gain). The far poles add a little delay but little else.

Dominance in a picture

Slow poles Close to the imaginary axis. They dominate.
Fast poles Far left. They die out quickly.
Rule of thumb Five to ten times farther.

Reduce the model to the dominant poles for quick design.

1 / 2

An extra pole slows the response

Start with the second-order system wn^2 / (s^2 + 2 zeta wn s + wn^2) with wn = 2 and zeta = 0.5, and multiply by p / (s + p), a first-order lag with unit DC gain. Small p (a pole near the origin) has a large effect; large p has almost none.

Python Adding a third pole

Press Run (or Ctrl + Enter) to see the result here.

Program input ยท what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

As p grows, the numbers approach those of the pure second-order system. At p = 20, ten times the real part zeta wn = 1, the extra pole is almost invisible. At p = 1 the overshoot shrinks sharply and the rise time grows, so a nearby extra pole "damps" the response while slowing it down.

A zero adds overshoot

Now multiply the second-order system by (s/z + 1), which adds a zero at -z and keeps the DC gain 1. A zero adds a scaled derivative of the output to the output, y + (1/z) y', so the response rises faster and overshoots more.

Python Adding a left-half-plane zero

Press Run (or Ctrl + Enter) to see the result here.

Program input ยท what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

The closer the zero is to the origin, the more it boosts overshoot and the earlier the peak. A zero far to the left is nearly harmless. This matters in control: a PD controller adds such a zero, which speeds the response and reduces effective damping loss, but amplifies the overshoot of the output relative to the error.

A zero and pole close together

If a pole and a zero lie close to each other, their effects nearly cancel except for a small, slow tail whose amplitude is proportional to the gap between them. The code below shows a stable second-order system with a nearby zero (a "doublet").

Python Near pole-zero cancellation

Press Run (or Ctrl + Enter) to see the result here.

Program input ยท what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

The maximum difference is small (about 0.01 to 0.02), so replacing the two nearby factors by nothing is an excellent approximation. A zero near a pole is nearly invisible in the output.

Practical consequences

  • Model reduction: keep the dominant poles and drop distant ones, remembering to preserve the DC gain.
  • Sensor and filter lags add poles that slow a loop and reduce stability margins, as seen in later chapters.
  • Zeros make the response faster but amplify overshoot and noise; a right-half-plane zero limits the useful bandwidth.
  • Always check by simulation because the rules are approximations.

Check your understanding

Quick check ยท 4 questions

of 4 answered You scored / 4 ยท perfect!

  1. 1. Which poles dominate the transient response of a stable system?

    Poles near the imaginary axis correspond to slow decaying modes that last longest.
  2. 2. Adding a pole to the left of a second-order system, close to its dominant poles, tends to

    An extra pole adds lag: the response is slower and the overshoot is reduced.
  3. 3. Adding a left-half-plane zero near the dominant poles tends to

    A zero contributes a derivative term, so the output rises sooner and overshoots more.
  4. 4. A pole at -3.0 and a zero at -3.1 are in the same system. Their combined effect is

    Close pole-zero pairs nearly cancel, leaving a tail whose size is proportional to the gap.

Summary

  • Poles closest to the imaginary axis dominate; poles 5 to 10 times farther left can usually be ignored (keep the DC gain).
  • An extra pole slows the response and reduces overshoot.
  • A left-half-plane zero speeds the response and increases overshoot; a right-half-plane zero causes undershoot.
  • Nearby pole-zero pairs nearly cancel.
  • Reduced models speed up design, but verify with a full simulation.

Next: Stability and Pole Locations