Chuyển đến nội dung

Bài 35 · Projects and Practice

Project: Cruise Control

Build a car cruise controller step by step: model the vehicle, tune a PI controller from pole placement, reject a hill disturbance, and add anti-windup for saturated engine force.

Cruise control is the textbook control problem that everyone has used. You set a speed; the car keeps it on flat roads, uphill and downhill. In this project you build the whole thing in simulation: a physical model, a PI controller designed from the closed-loop poles, a disturbance (a hill), and the real-world complication of a limited engine force. Along the way you use ideas from the PID chapter and the practical PID lesson.

flowchart LR
    R["set speed r"] --> E(("+/-"))
    E -->|"e"| C["PI controller"]
    C -->|"force F (limited)"| V["Car: m v' = F - b v - m g sin(theta)"]
    H["hill slope theta"] --> V
    V -->|"speed v"| E

The cruise-control loop with a hill as an external disturbance.

Step 1: the model

Newton's second law along the road gives

TEXT
m·v' = F - b·v - m·g·sin(θ)

where m is the mass, F the engine force (our control input), b·v linear drag (a simplification of the real quadratic drag) and m·g·sin θ the gravity component on a slope θ. With m = 1200 kg and b = 50 N·s/m, the plant V(s)/F(s) = 1/(m s + b) is a first-order lag with a long time constant m/b = 24 s: the car coasts for a long time. The engine can deliver at most ±3000 N (braking included, to keep the example simple).

At a steady 25 m/s (90 km/h) on flat ground the engine must supply b·v = 1250 N to cancel drag. On a 5° hill it needs 1250 + m g sin 5° ≈ 2276 N, which is within the limit, so the car can hold speed on that hill.

Step 2: a PI controller from the poles

A P controller alone would leave a steady-state error (it needs a nonzero error to produce the drag force). So use PI: F = Kp·e + Ki·∫e. Closing the loop around 1/(m s + b) gives the characteristic equation

TEXT
m·s² + (b + Kp)·s + Ki = 0

Compare with the target s² + 2ζωn s + ωn²: multiply through by m to get Kp = 2ζωn·m - b and Ki = m·ωn². Choose critical damping ζ = 1 and ωn = 0.5 rad/s (a time constant of about 2 s per pole), which gives Kp = 1150 and Ki = 300.

It is tempting to choose the PI zero to cancel the plant pole (Ki/Kp = b/m). Do not. The cancelled slow mode (time constant 24 s) still reacts to disturbances: the car would take over a minute to recover from a hill. Place the closed-loop poles directly instead.

Step 3: simulate the hill

The simulation uses small Euler steps. The hill begins at t = 40 s. The controller includes anti-windup (back-calculation) because the force limit matters during the start-up.

Python PI cruise control on a flat road, then a 5 degree hill

Press Run (or Ctrl + Enter) to see the result here.

Program input · what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

The speed reaches 95% of the target in about 13.5 s (the engine saturates during the first seconds, so this is slower than the linear design predicts). On the hill the car loses about 0.6 m/s and recovers to within 0.25 m/s in 6 s. The final engine force settles at 2276 N, exactly b·v + m g sin θ, which is what integral action should find without being told the slope.

Step 4: why anti-windup matters

Start from a standstill with a set speed of 25 m/s. The error is huge, so the controller demands far more force than the engine can give. Without anti-windup the integrator keeps accumulating while the force is limited, and the car overshoots the target badly.

Python The same PI controller with and without anti-windup

Press Run (or Ctrl + Enter) to see the result here.

Program input · what you'd type while the program runs

Type the answers before you press Run, one per line. Each time the program reads a line (with input()), it gets the next line from this box.

Without anti-windup the speed peaks at about 38.6 m/s (nearly 14 m/s above the set speed!) and takes 35 s to settle. With back-calculation the peak is the set speed itself and the settling time is 15.8 s. The cost of anti-windup is one line of code; the benefit is a car that does not run away after a standing start.

Step 5: extend the project

Try these extensions in the editors above:

  1. Quadratic drag. Replace b·v by 0.5·ρ·Cd·A·v² (for a car, about 0.4·v²). The loop gain now depends on speed; check the response at 10 and 35 m/s.
  2. Measurement noise and a speed filter. Add noise to v and see how much it moves the force; add a low-pass filter on the measured speed.
  3. Gear shifting. Make the maximum force a function of speed, as an engine has a torque curve.
  4. Comfort limit. Limit the acceleration to 2 m/s² by rate-limiting the set speed. This shortens the saturation time at the start and reduces overshoot (but keep anti-windup too).
  5. Downhill. Use a negative slope; the car must brake or coast. What happens when the engine can only push, not brake?

What you learned

  • A plant with a very slow pole should not be cancelled; use pole placement on the closed-loop polynomial.
  • Integral action finds the unknown disturbance force; the final controller output equals what the disturbance requires.
  • Actuator limits change the start-up behavior and make anti-windup essential.
  • Simple simulations expose these effects long before a test drive does.

Check your understanding

Quick check · 4 questions

of 4 answered You scored / 4 · perfect!

  1. 1. For the car m v' = F - b v - m g sin(theta) with a PI controller, what is the characteristic equation of the closed loop?

    Closing the loop around 1/(m s + b) with C(s) = Kp + Ki/s gives m s^2 + (b + Kp) s + Ki = 0.
  2. 2. Why does the final engine force on a hill equal b v + m g sin(theta)?

    In steady state v' = 0, so F must equal drag plus the gravity component; the integrator finds that value.
  3. 3. What goes wrong if you cancel the slow plant pole with the PI zero?

    Cancellation hides the slow mode from the set-point response but not from disturbances that enter at the plant input.
  4. 4. Which problem does anti-windup solve in this project?

    With the force limited, the integral keeps growing and causes a large overshoot after a standing start.

Summary

  • Model: m v' = F - b v - m g sin θ; a slow first-order plant with a force limit.
  • Design a PI controller by matching m s² + (b + Kp) s + Ki to the desired poles; do not cancel the plant pole.
  • Integral action rejects the hill; the integrator ends up holding the required force.
  • Anti-windup avoids a large overshoot after saturation.

Next: Project: Inverted Pendulum with LQR

Theo dõi tiến độ của bạn

Tạo tài khoản miễn phí để đánh dấu bài đã học và tiếp tục từ chỗ bạn dừng lại trên mọi thiết bị.